ID60 Enhanced One-Loop Control Panel

ID60 single loop intelligent fire alarm panel

The NOTIFIER ID50/ID60 range of single-loop intelligent fire alarm panels, has been developed for both installers and end users with efficiency in mind, offering a technically advanced range of facilities and functions whilst remaining easy to install, program and operate.

With the capacity to protect up to 16 zones, NOTIFIER ID50 and ID60 series control panels are capable of monitoring up to 99 heat, smoke or multi-criteria sensors plus 99 call points.

Complementing the ID60 range, a full range of intelligent sensors (including the VIEWTM high sensitivity smoke detector), advanced detection products, input and output devices, repeaters, mimic drivers, printers and other peripherals are supported.

Pearl 1 Loop Addressable Control Panel

PRL-LED-EN-1

The earl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifier’s class leading Opal digital protocol to maximize the speed and efficiency of fire detection and alarm.

Automatic Fire Detection: Opal Optical Smoke Detector

NFX-OPT/NFXI-OPT

The Opal photoelectric smoke detector has a completely new detection chamber design, the result of many years of research and development. This delivers improved responsiveness, reduced sensitivity changes caused by settling dust and reduced false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing filters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms. The devices are managed by embedded software running complex algorithms that further improve resilience to false alarms and improve detection speed

Automatic Fire Detection: Opal Heat detector, fixed 58C

NFX-TFIX58/NFXI-TFIX

The Opal NFX-TFIX58 & NFX-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58°C (Class A1S) to 78°C (Class BS). The Opal NFX-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10°C/minute (typical) or if the temperature exceeds a threshold of 58°C (Response Class A1R). With the implementation of the advanced protocol, any model can be software configured to be either a fixed 58°C, a fixed 78°C unit or a 58°C with rate of rise device. For backwards compatibility and approval continuity, three separate versions continue to be available as separate part numbers.

Automatic Fire Detection: Remote Indicator Unit

RI/W/3V

The RI/W/3V remote indicator unit is designed for fi re detection systems requiring local indication of an individual or group of fire detectors in alarm. The unit is fitted with LED providing a wide area of illumination and high on/off contrast for easy viewing.

Using a single gang purpose designed moulding, the unit operates with all Notifi er analogue addressable fi re detectors.

Manual Detection: Addressable Indoor Call Point

M700KACI

Addressable call point. M700KACI-FG supplied with Glass element. M700KACI-FF supplied with Flexible Element. Requires SR1T for surface mounting, terminal tray ETT-P and single gang back box for semi flush mounting.

Manual Detection: Red Call Point Back Box

SR1T

Single terminal surface back box for call points